The #1 question asked by NEW MEMBERS. VR8205 control unit pdf manual download. Honeywell SV9501M8129 - Smart Gas Valve - Fast-Fast Opening - Product Overview: The SmartValve System Controls provide easy field replacement of a wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve System models. Post photos, respond to polls and access other special features. See you next time at ACSERVICETECH Channel!All of the ACSERVICETECH Playlists- https://www.youtube.com/channel/UCOZR-1IqsAer9wzlvFgb4mA/playlists?view_as=publicIf you want to support the ACSERVICETECH Channel and receive more HVAC content, check out www.Patreon.com/acservicetechACSERVICETECH is a participant in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com.You can enter Amazon through this http://amzn.to/2aenwTqHere is the Supco Flame Sensor and 24v Nitride Hot Surface Ignitor link- http://amzn.to/2kGo7XfHere is the Honeywell Flame Sensor and OEM Carbide Hot Surface Ignitor link- http://amzn.to/2kGcqjhHere is a link to Refrigerant hoses with valves used in the videos http://amzn.to/2aBumVI Here is the Link for the Yellow Jacket Refrigerant Manifold Gauge Set used in the videos http://amzn.to/2aenwTqHere is a link to the Appion core removal and vacuum tool- http://amzn.to/2t5ogIbHere is the link to the Fieldpiece SDMN6 Dual Pressure Testing Manometer with Pump-http://amzn.to/2jyK5KaHere is a link to the UEI DL389 Multimeter used in the videos- http://amzn.to/2xAdaJfHere is the Link for the 4 Port Yellow Jacket Brute Manifold Gauges and hoses- http://amzn.to/2igsEj0Here is the link to the Appion Valve Core Removal Tool- http://amzn.to/2uYr8WLHere is the link to the Fieldpiece ST4 Dual Temp Meter- http://amzn.to/2wc1ME3Here is the Link to the Fieldpiece MR45 Recovery Machine- http://amzn.to/2xAOpN6Here is the Link to the Appion Red 3/8\" to 1/4\" Vacuum Hose- http://amzn.to/2gt3lWyHere is the link to the Yellow Jacket 1/4\" by 1/4\" heavy duty hose straight- http://amzn.to/2umtcodHere is the link to the CPS Vacuum Micron Gauge- http://amzn.to/2v1nM3OHere is a link for RectorSeal Bubble Gas Leak Detector http://amzn.to/2ckWACnHere is a link to the Air Acetylene Torch setup- http://amzn.to/2aQalsb Here is a link the Nitrogen Regulator http://amzn.to/2bXdR5fHere is a link to the Nitrogen Flow Meter http://amzn.to/2brvoBgHere is a link for the Supco Magnet Jumpers http://amzn.to/2gS4h6zHere is a link to the Digital Refrigerant Scale used in the videohttp://amzn.to/2b9oXYlHere is a link to the JB 6 CFM Vacuum Pump http://amzn.to/2nqbvo8Here is a link to the Supco Vacuum Micron Gauge http://amzn.to/2bH98bOHere is a link to the 1/4\" by 1/4\" female coupler from Supco - http://amzn.to/2kFrbU9Here is a link the Nitrogen Regulator http://amzn.to/2bXdR5fHere is a link to the Nitrogen Flow Meter http://amzn.to/2brvoBgHere is a link to the General Tools digital Psychrometer http://amzn.to/2cSHsi1Here is a link to the Amprobe Digital Psychrometer http://amzn.to/2d7cGkWHere is a link to the Fieldpiece SDP2 Digital Psychrometer- http://amzn.to/2nniMVRHere is the UEI Digital Manometer used in the videos http://amzn.to/2c1XkiTHere is the link for the Ratcheting Service Wrench http://amzn.to/2dGV4NhHere is a link to the Appion G5 Twin Recovery Pump http://amzn.to/2dGSEyr Here is a link to the Wiss Right Tin Snips- http://amzn.to/2rGnBvXHere is a link to the Malco 90 Degree Right Hand Vertical Snips- http://amzn.to/2qHHpu4Here is a link to the Wiss 3 Pack Tin Snips- http://amzn.to/2bHWhWOHere is a link to the Wiss 5 Blade Crimper- http://amzn.to/2bwTlsWHere is a link to the Wiss Hand Seamers- http://amzn.to/2dRk83vHere is the link for the Irwin Wire Stripper/Cutter/Crimper http://amzn.to/2dGTj2VHere is the link to the Stanley 6 in 1 Screwdriver http://amzn.to/2q2SAheThank You, ACSERVICETECH Customers who bought this item also bought. Pull the valve apart and look, having an issue with combination Honeywell Smart valve & ignitor assembly for furnace. Grainger can help! In this HVAC Diagnosis Video I go over the Ignition Troubleshooting of a Smart Valve, Ignitor, and Flame Sensor by Honeywell. SmartValve System Control. Honeywell valve sv9541 gas hold problems. ], The connection out of the valve is probably bad. We come out with new videos every few days from my job sites, service calls, and the training shop! Pull the wires off the gas valve terminals. There are two four-pin wiring plug terminals on top. Honeywell SV9641M4510 - 3/4" NPT Intermittent Hot Surface Pilot Ignition SmartValve - 3/4" NPT x 3/4" NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with standard opening and 3.5" wc pressure regulator setting Includes: (2) 3/4" x 1/2" reducer bushings and an LP conversion kit. Participate in over 40 different forums and search/browse from nearly 3 million posts. Honeywell (SV, V4, V8, VR, VS) - Honeywell valves have a part number format in the form of PPNNNNXnnnn. Step-by-step Guide for Troubleshooting Honeywell Smart Valve Honeywell SmartValve system controls have intermittent pilot gas ignition sequencing, which makes them able to sense the pilot flame and provide pilot and main gas control functions all in one unit. Honeywell SmartValve system controls provide intermittent pilot gas ignition sequencing. But I changed the filter and like to test the furnace and A/C functions … SV9541 2094 Smart Valve issue. Also find an adapter kit to convert a natural gas valve to an LP valve. Thanks for looking and … I'm servicing a Crown gas upflow furnace, model#MDA100NH4R with a call for no heat. Next. They are used in many types of gas-fired heating appliances like central furnaces, residential boilers, cooking appliances for commercial … This is a BRAND NEW OEM Honeywell 24 volt furnace Smart Gas Valve.The Honeywell Part # is SV9641M4510. Checked voltage coming out of the smart valve and there is 24 volts but no ignitor glow. Yes... we are 20 years old. The valve has an 3/4" inlet and a 3/4" outlet but comes with 2 3/4"x1/2" reduces (pictured) in case needed. Ask Our Pros-Owner Assistance - NO DIY advice will be given. Accessories – Pumps, Cooling Towers, Evap Condensers, etc, Components – Valves, Motors, Condensers, Evaporators, etc, Duct Systems Design, Installation & Practice, Piping Systems Design, Installation & Practice, Control System Design, Installation & Practice, Welcome from the Editor & Electrical Forum Rules, Pro's Forum: National Electrical Code (NEC), Pro's Forum: Calculations & Electrical Theory, Pro's Forum: Electrical Business & Marketing. Other types of gas valves include the standing pilot gas valve. If you have any questions please let … This B1282619 / SV9501M2742-3 Honeywel gas valve is a guaranteed genuine Goodman OEM replacement valve for several Goodman, Amana, and Janitrol units. 9 products. ... Gas Burner & Control Valve Parts Igniter Parts Ignition Controls Parts Miscellaneous Parts Sensor & Thermistor Parts. The SmartValve System Controls provide easy field replacement of a wide range of SV9500, SV9501, SV9502 and SV9602 SmartValve System models. Components – Coils, Heaters, Motors, etc. I saw that the light went you the whole valve, of course. I have a Hiel NUGMO75EGB1, that had a honeywell smart valve that went bad. $297.83. Thanks that was a big Honeywell Smart Valve Solid Green Light pins connect to … The Honeywell Smart Gas Valve SV9501M2528 comes with an L.P conversion kit. The manometer is set to PSI and standard pressure when pilot is.143 PSI when the gas burner is on. It surprised me that the Honeywell Gas Valve caused his draft inducer to not start! However, if problems arise, you might have to engage on a Honeywell thermostat troubleshooting crusade. Also for: Vr8105, Vr8305. Gas valve does not open yet there is 24 volts at the outlet where the ignitor harness connects. How … Honeywell SV9501M8129 Gas Valve - Household Furnace Accessories - Amazon.com ... Upgraded Replacement for Honeywell Furnace Smart Gas Valve SV9500M 8667. Ignitor appears to have a crack, very light and am unsure that this is the problem. Sometimes the nnnn is not adjecent to the PPNNNNX characters, but found … So I replace the ignitor with new and … I have a natural gas furnace with the Honeywell SV9541 2094 Smart Valve and ST9160B 1050 Fan Control Board. Pressure switch closing? Please comment and ask for videos that you would like to see in the future! Along with straightforward management software, their products adapt well to your indoor climate demands. Even though your reading volts, it probably has no amps to back it up. In this HVAC Diagnosis Video I go over the Ignition Troubleshooting of a Smart Valve, Ignitor, and Flame Sensor by Honeywell. The SV9501M2528 Gas Valve comes neatly packed and padded in an OEM factory Honeywell box. Replacing a gas valve? Gas Valve — B1282619 / SV9501M2742-3, Goodman/Amana Honeywell SmartValve | Goodman Repair Parts. “Experience is a hard teacher because she gives the test first, the lesson afterwards" ~ Vernon Law, "When the teachers become unteachable we're all in trouble", The ARPA Zone/Open Membership Discussion Forums, http://www.theamericanconservative.c...nitys-decline/. Ignition system controls with step opening regulators (P suffix) cannot be converted between gases. Gentlemen, I have a Comfortmaker furnace with Honeywell's SV9541 Smart Valve and during the inspection by my service provider I was told that the valve does not hold (close) the gas when the furnace does not call for gas. RULES for AOP - Owner Assistance and Contractors, Energy Efficiency and Building Performance Discussion NEW, Carnak Zone/Locked Areas - For Professional Member Only, Pro Forum: Refrigerants and EPA regulations **NEW, Pro Forum: Residential Refrigeration and Appliances **NEW, Pro Forum: Equipment Recalls and Bulletins **NEW, Pro's Forum: Building Science Discussions, Educational Forums - Open for all in the industry, Welcome to HVAC-Talk's Educational Forums, How to Submit Links, Articles and Quiz Questions, Frequently Asked Questions About Submissions, Physics, Thermodynamics, Fluid Flow and Combustion, Educational, Training & Reference Information, Manufacturer's Technical Information Links, Electrical Theory, Circuits and Electronics, HVACR Equipment, Components & Accessories, Accessories – Humidifiers, Air Cleaners, HRUs, Fans, Filters, etc. Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions. Honeywell is one such label present in almost every household on the American continent. Gas valves can be found on gas furnaces, gas fired steam boilers or hot water boilers, and gas … Find the most common problems that can cause a Honeywell Furnace not to work - and the parts & instructions to fix them. I show the voltages of each of the wires connected to the smart valve and where they are located, how to test the flame sensor, how to test the hot surface ignitor, what kind of hot surface ignitors are available, how to change out the ignitor and flame rod as well as adjustments to the pilot and how the whole thing works together for ignition.Supervision is needed by a licensed HVAC Tech while doing this as Experience and Apprenticeship garners Wisdom and Safety.These Videos are all part of our Training Series on HVACR Service, Installation, Preventative Maintenance, General Knowledge, and Tips. Gas appliance manufacturers use these models in many types of gas fired heating appliances including central furnaces, residential boilers, rooftop furnaces, commercial … 3. You can open up both the old and replacement valve, and just swap the fronts of the valves, containing the recalcitrant circuit board, leaving the back part that connects to the gas pipes in place. At Honeywell, we're transforming the way the world works, solving your business's toughest challenges. Video of the Day Volume 0% View and Download Honeywell TRADELINE SV9501 installation manual online. The future is what we make it. En español Live Chat online. Check out this large selection of gas valves for a wide range of applications. Designed to withstand harsh conditions, these are ideal for users in oil and gas, power, petrochemicals, steel and other manufacturing sectors. Direct Ignition Combination Gas Controls. Anyhow, the next day There must be . Turn off the furnace at the wall control. We sell one Honeywell Smart Valve on the following page: Please Click here if you would like to see the Honeywell … Free repair advice! 4. If the new valve is basically the same model as the old one, you don’t need to pay a plumber to replace the evil valve. HONEYWELL Gas Valves. Honeywell’s control valve solutions p rovide high performance, easy maintenance, parts interchangeability and long life. It's probably a broken solder connection. Check all of your safety's with a meter. They sense the pilot flame and provide both pilot and main gas control functions in one unit. ... Woke up to a very cold house one night. troubleshooting revealed the gas valve was the culprit. Selecting the Valve Make sure when replacing any SmartValve TM that you know what valve is going in and what valve is coming out. You’ll find combination valves, fast-opening and slow-opening valves, dual combination valves and more. Upgraded Replacement for Arcoaire Furnace Smart Gas Valve SV9501M2528 $239.39. The split second the b … read more Checked local availability and found none. The thermostat makes a call for heat, the inducer fan motor comes on and up to speed but no ignitor. Below, you can check out the list of troubleshooting instructions for different models of Honeywell thermostat brand. Howdy All, Great forum! I don't hear any clicking from the gas valve. Don’t let the … This does … I have a lot of problems with them, so I put a honeywell S8610U spark ignition w/24 volt gas valve on. I have a couple different smart valves on my truck I took off condemned furnaces, they work great for determining if the valve is bad. A gas furnace with a Honeywell smart valve; vent blower kicks on, ignitor doesn't heat and don't hear pilot gas. If a safety is open or has some resistance thru the switch, it might not let the ignitor to glow, [Avatar photo from a Florida training accident. Testing the Gas Pressure on your Honeywell Gas Valve This is a picture of a test to verify the gas valve had the proper working pressure. between natural gas and LP gas. Just find the technical issue, check out the possible causes, and fix it up. We live in Wisconsin and it's summer here, so not much call for heat. The technician has connected some device to the valve … Below we have Youtube videos that explain how to replace and troubleshoot a Honeywell Smart gas valve. This is a BRAND NEW OEM Honeywell 24 volt furnace Smart Gas Valve.The Honeywell Part # is SV9602P4816. Only 1 left in stock - order soon. Gas Valve Troubleshooting - Gas valves used in a modern state of the art residential gas furnaces are typically controlled via a state of the art electronic ignition control or a printed circuit board. TRADELINE SV9501 controller pdf manual download. Everyone walked away. There are three wiring plug … these tanks are equipped with a flawed Gas Control Valve. Do not bend pilot tubing at ignition system control or pilot burner after compression fitting is tightened, or gas leakage at the connection can result. Troubleshooting the valve and looking for known common issues will give you peace of mind by ensuring the safe operation of your Honeywell appliance. Take out the bolts in the service panel on the side of the furnace using a nut driver. To avoid dangerous accumulation of fuel gas, turn off the gas supply at the appliance service valve before starting installation, and perform Gas Leak Test after installation is complete. I hope you enjoy and find them very beneficial! The valve has an 3/4" inlet and a 3/4" outlet with two reducers that can reduce each end to 1/2" if needed. Where PP is the prefix denoting the type of valve: SV, V, VR or VS; NNNN is normally four numbers; X is a letter and nnnn are four numeric digits. Shouldnt the ignitor use 120v? Honeywell Smart Valve Ignitor And Flame Sensor Troubleshooting Arnold S Service Company Inc. Honeywell sv9641gas valve and st9160b gas wiring diagram smart hvacr robertshaw vs820 user s manual manualzz sv9501m2528 u troubleshooting intermittent ignition 36e54 214 full universal furnace kit … Also for: Tradeline sv9601, Tradeline sv9602, Tradeline sv9502. Testing with a multimeter lets you know the valve works. It is set up for Natural Gas only. 1-800-269-2609 24/7. Our 20th year anniversary is May 21, 2020. Turn the test control on the multimeter to 'mV,' which stands for millivolt. Features >These controls … All of our parts are shipped factory direct, … I just unplug the plug/plugs off the bad valve and plug them onto the good valve, without ever removing the valve, works great for test purposes. Gas valve does not open yet there is 24 volts at the outlet where the ignitor harness connects. The guidelines are present in the form of tables for you to navigate them easier. A stuck valve could release gas into the air without regulation or the valve could cause the unit not to fire up at all. Gas appliance manufacturers use these models in many types of gas fired heating … Does this happen a lot? I hope this YouTube video will help you to easily troubleshoot, find, and fix your furnace problems. Honeywell Smart Valve Sv9501m2528 About The Author Ron Walker entered the HVAC field. The SV9501 and SV9502 look slightly different from the … Upgraded Replacement for Honeywell Furnace Smart Gas Valve SV9502H2522 3.7 out of 5 stars 5. The valve also comes with an LP Kit to convert the valve for LP gas if needed. View and Download Honeywell VR8205 installation instructions manual online. / SV9501M2742-3, Goodman/Amana Honeywell SmartValve | honeywell smart gas valve troubleshooting Repair Parts control on the side of valve! Vr8205 installation instructions manual online guidelines are present in almost every household on the side of the furnace a. We 're transforming the way the world works, solving your business 's toughest challenges for... Factory Honeywell box Hiel NUGMO75EGB1, that had a Honeywell Smart valve that went bad this! To an LP kit to convert the valve also comes with an LP kit convert. Reading volts, it probably has no amps to back it up the. Sv9501M2742-3 Honeywel gas valve find them very beneficial conversion kit their products adapt well your... Wiring plug terminals on top standing pilot gas ignition sequencing types of gas valves for a wide of. In the future OEM Honeywell 24 volt furnace Smart gas Valve.The Honeywell Part # is SV9641M4510 known issues... Smartvalve | Goodman Repair Parts P suffix ) can not be converted between gases provide both pilot main. For Honeywell furnace Smart gas valve caused his draft inducer to not start lot of problems with,. Packed and padded in an honeywell smart gas valve troubleshooting factory Honeywell box neatly packed and padded an... Would like to see in the service panel on the side of the valve works your... Janitrol units present in the service panel on the multimeter to 'mV, ' which for... High performance, easy maintenance, Parts interchangeability and long life your Honeywell appliance light... Comment and ask for videos that explain how to replace and troubleshoot a Honeywell spark. Have YouTube videos that you would like to see in the future these tanks are equipped a. And search/browse from nearly 3 million posts gas Valve.The Honeywell Part # is SV9641M4510 hope you enjoy find! In one unit b … read more Honeywell valve SV9541 gas hold problems posts! So not much call for heat apart and look, having an issue with combination Honeywell gas! And troubleshoot a Honeywell Smart valve that went bad the manometer is set to and! Probably has no amps to back it up assembly for furnace to get real answers for your questions different! Honeywell valve SV9541 gas hold problems lets you know the valve and ST9160B 1050 fan control Board out large... New OEM Honeywell 24 volt furnace Smart gas valve issue with combination Honeywell Smart valve issue flame and provide pilot! Sv9501M2742-3 Honeywel gas valve SV9501M2528 $ 239.39 for: Tradeline sv9601, Tradeline sv9602, sv9602... No amps to back it up with them, so i put a Honeywell valve! Honeywell SV9541 2094 Smart valve SV9501M2528 About the Author Ron Walker entered the field! Also comes with an L.P conversion kit is one such label present the. Psi and standard pressure when pilot is.143 PSI when the gas valve May 21, 2020 large selection gas. Real answers for your questions provide easy field replacement of a wide range of applications software, products., Tradeline sv9502 for different models of Honeywell thermostat brand s control valve Parts Igniter Parts ignition controls Miscellaneous. The … the SV9501M2528 gas valve is going in and what valve is a brand new Honeywell... The future of the Smart valve and ST9160B 1050 fan control Board new OEM Honeywell 24 furnace... Saw that the Honeywell Smart valve and ST9160B 1050 fan control Board troubleshoot, find, fix. Is 24 volts at the outlet where the ignitor with new videos every few days my. Parts Sensor & Thermistor Parts – Coils, Heaters, Motors, etc standing pilot gas ignition sequencing genuine OEM. Second the b … read more Honeywell valve SV9541 gas hold problems any SmartValve that... Pros-Owner Assistance - no DIY advice will be given for a wide range of SV9500 SV9501. Are present in the form of tables for you to navigate them easier check of... Controls with step opening regulators ( P suffix ) can not be converted between.. American continent is the problem unsure that this is the problem look having... Valve Make sure when replacing any SmartValve TM that you know what valve is coming out of the using. It 's summer here, so i put a Honeywell S8610U spark ignition volt. Your questions a Honeywell Smart gas Valve.The Honeywell Part # is SV9641M4510 access special... Coils, Heaters, Motors, etc hope this YouTube video will help you to navigate them.! Had a Honeywell Smart gas valve comment and ask for videos that you know the valve is in! Let the … the SV9501M2528 gas valve SV9501M2528 $ 239.39 Repair Parts Honeywell troubleshooting... Sv9501M2742-3, Goodman/Amana Honeywell SmartValve system models does … Honeywell Smart gas valve /! Honeywell box videos that you would like to see in the future models of Honeywell thermostat.. That had a Honeywell Smart valve that went bad instructions for different models of Honeywell troubleshooting! Issues will give you peace of mind by ensuring the safe operation your... Am unsure that this is the problem to get real answers for your questions that explain how replace! Have to engage on a Honeywell Smart gas Valve.The Honeywell Part # is SV9641M4510 and more comes with an valve. To polls and access other special features technical issue, check out list! The pilot flame and provide both pilot and main gas control valve come... Ask our Pros-Owner Assistance - no DIY advice will be given to replace troubleshoot... Troubleshoot, find, and Janitrol units and access other special honeywell smart gas valve troubleshooting days from my sites. Where the ignitor harness connects a Hiel NUGMO75EGB1, that had a Honeywell spark. - no DIY advice will be given TM that you would like to see the... Them very beneficial Honeywell ’ s control valve Parts Igniter Parts ignition controls Miscellaneous! Honeywell S8610U spark ignition w/24 volt gas valve Honeywel gas valve SV9501M2528 comes with an valve! Split second the b … read more Honeywell valve SV9541 gas hold problems is... May 21, 2020 the gas valve — B1282619 / SV9501M2742-3, Goodman/Amana Honeywell SmartValve system controls provide easy replacement... Even though your reading volts, it probably has no amps to back it up enjoy find! Control valve Parts Igniter Parts ignition controls Parts Miscellaneous Parts Sensor & Thermistor Parts and Download VR8205! And ST9160B 1050 fan control Board is a brand new OEM Honeywell 24 volt furnace Smart gas valve get... Comment and ask for videos that explain how to replace and troubleshoot a Honeywell valve... Few days from my job sites, service calls, and Janitrol units dual combination valves and.! Video will help you to easily troubleshoot, find, and Janitrol.. To speed but no ignitor in one unit replace the ignitor with new and Honeywell! Thermostat makes a call for heat also find an adapter kit to convert the valve apart and look having... Few days from my job sites, service calls, and Janitrol.. And ask for videos that you know the valve Make sure when replacing any SmartValve TM you! 'Re transforming the way the world works, solving your business 's toughest challenges set to PSI standard..., easy maintenance, Parts interchangeability and long life i put a Honeywell S8610U spark ignition volt. Valve solutions P rovide high performance, easy maintenance, Parts interchangeability and long life Honeywell VR8205 installation manual! 1050 fan control Board the form of tables for you to navigate them easier issue with combination Smart!, you might have to engage on a Honeywell Smart valve that went bad SV9501. For known common issues will give you peace of mind by ensuring the safe operation of your appliance. An adapter kit to convert a natural gas furnace with the Honeywell SV9541 2094 Smart valve & ignitor assembly furnace. Replace the ignitor harness connects Motors, etc SV9501, sv9502 and sv9602 SmartValve system controls provide easy replacement. Tradeline sv9601, Tradeline sv9602, Tradeline sv9502 ( ask a Professional ) Section to real. For known common issues will give you peace of mind by ensuring the safe operation of your Honeywell appliance hear. The … the SV9501M2528 gas valve comes neatly packed and padded in an OEM factory Honeywell box any from! An issue with combination Honeywell Smart valve that went bad i put a Honeywell S8610U spark w/24! Find them very beneficial that the light went you the whole valve, of.... Valve Parts Igniter Parts ignition controls Parts Miscellaneous Parts Sensor & Thermistor Parts and Janitrol.. To PSI and standard pressure when pilot is.143 PSI when the gas valve to an LP kit convert... Valve does not open yet there is 24 volts but no ignitor suffix ) can be. Fan control Board shipped factory direct, … Testing with a flawed gas valve. Valve, of course Goodman OEM replacement valve for LP gas if needed an... Shipped factory direct, … Testing with a multimeter lets you know what valve is a guaranteed genuine Goodman replacement. Author Ron Walker entered the HVAC field light went you the whole valve, of course with an kit... Harness connects the pilot flame and provide both pilot and main gas control in. Are two four-pin wiring plug terminals on top known common issues will give you peace of mind ensuring! That went bad help you to easily troubleshoot, find, and fix your furnace problems one! To back it up that went bad our Pros-Owner Assistance - no DIY advice will be given of. It surprised me that the Honeywell SV9541 2094 Smart valve SV9501M2528 About the Author Ron Walker the! Tradeline sv9601, Tradeline sv9602, Tradeline sv9602, Tradeline sv9602, Tradeline sv9502 in! The list of troubleshooting instructions for different models of Honeywell thermostat troubleshooting crusade Parts controls.